Skip to main content

Weathering test systems

Reliable weathering tests

Core performance data:

Black panel temperature:
+50 °C to +95 °C +/-1 °C
Relative humidity:
50 % RH +/- 5 % RH at 60 °C BPT and 180 W/m²
Sample room temperature:
38 °C +/-2 °C
Relative humidity (dark cycle):
95 % RH +/-5 % RH
Reliable weathering tests

Core performance data:

black panel temperature:
+63 °C to +110 +/-2 °C
relative humidity:
50 % RH +/- 5 % RH. at 63 °C BPT and 60 W/m²
sample room temperature:
38 °C +/-2 °C
Relative humidity (dark cycle):
95 % RH +/-5 % RH
Reliable weathering tests

Core performance data:

Black panel temperature:
+63 °C to +110 +/-2 °C
Relative humidity:
50 % RH +/- 5 % RH at +63 °C BPT and 60 W/m²
Sample room temperature:
+38 °C +/-2 °C
Relative humidity (dark cycle):
95 % RH +/-5 % RH

Frequently asked questions about weathering test systems:

For which test standards are SUGA weathering devices suitable?

Our systems are suitable for many common norms and industry standards, for example: SO 4892-2, ISO-16474-2, ASTM D6695, ISO 105-B02, ISO 105-B04, ISO 105-B06, SAE J2527, SAEJ2412, PV1303, PV3929, PV3930 and many more. Please do not hesitate to contact us.

Which aspects should be particularly emphasised/ In which aspects do you differ from the competition?

Our many years of experience and in-house production of xenon lamps are particularly noteworthy. In combination with the maximum possible number of samples, SUGA offers a unique overall concept in the field of weathering tests.

Do you have any questions about our product world? May I help you?

We are happy to offer you advice from a specialised member of our team:

Florian Häusel

+49 (0) 6471/6293-220

This email address is being protected from spambots. You need JavaScript enabled to view it.