Skip to main content

Special Applications


Optimal testing solution for 5G devices

Core performance data:

Temperature range:
-40 °C to +100 °C
Frequency range:
0.5 GHz to 30 GHz
Attenuation:
60 dB and more
Inner dimensions:
WHD (mm) 14000 x 3000 x 7000
HALT/ HASS test system

Core performance data:

Temperature range:
from -100 °C to +200 °C (expandable to +250 °C)
Change rate:
of approx. 70 K/min on average
Temperature deviation:
+/- 1K
Sizes:
available in various sizes
Excellent reproducibility and linearity

Core performance data:

Suitable for samples:
of approx. 30 mm x 50 mm to 70 mm x 300 mm and a thickness of 0.8 to 4 mm
Standard friction movements:
(back and forth) of 40 per minute
Optional friction movements:
60 possible
Efficient Scanner Technology

Core performance data:

Test and metering voltage:
Stable and uninterruptible test and measurement voltages of up to 2.500 V
Measuring range:
Wide measuring range from 2 x 103 up to 1x1014Ω
Continuous measuring with scanning rate up to 100 μS
Monitoring the contact resistance

Core performance data:

Basic model:
Monitoring of 40 channels
If required:
Expansion to 280 channels possible
Precision:
Very high precision in measuring ranges between 10-3 and 106 Ohm (1mOhm to 1MOhm)

Do you have any questions about our product world? May I help you?

We are happy to offer you advice from a specialised member of our team:

Florian Häusel

+49 (0) 6471/6293-220

This email address is being protected from spambots. You need JavaScript enabled to view it.